Watch Tower

Watch Tower

PCAP File

The packet capture is of Modbus/TCP.

Modbus

Modbus is a communication protocol developed in 1979 by Modicon (now Schneider Electric) for industrial automation systems. It enables data exchange between electronic devices like PLCs (Programmable Logic Controllers), sensors, HMIs (Human-Machine Interfaces), and other industrial equipment.

  • Master/Slave (Client/Server) Architecture: One master (client) controls communication with multiple slaves (servers).
  • Function Codes: Define operations like read/write coils (digital I/O), registers (analog data), diagnostics, etc.

Common Use Cases

  • Factory automation (robotics, conveyors).
  • Energy management (smart meters, solar inverters).
  • Building automation (HVAC, lighting systems).
  • Water treatment plants.

Modbus/TCP

Modbus/TCP is the Ethernet-based version of the Modbus protocol. It takes the same simple Modbus frame format and wraps it inside standard TCP/IP packets instead of sending it over a serial line. That single change gives Modbus the speed, distance, and flexibility of modern Ethernet networks while keeping the familiar register/coil data model and function codes.


One thing I noticed on each packet was a Unit number and a Function number. What do they mean?

Unit and Function Numbers

NumbersIn Modbus terminologyWhat it actually does
Unit = 1, Function = 1Read Coils (FC=01)The master/client asks slave/server with address 1 to return the ON/OFF state of one or more coils (digital outputs or internal relays).
Unit = 1, Function = 15Write Multiple Coils (FC=15)The master tells slave 1 to turn ON or OFF a consecutive block of coils in a single message.
Unit = 1, Function = 16Write Multiple Registers (FC=16)The master writes one or more 16-bit holding registers (analog outputs, set-points, configuration words, etc.) to slave 1.
  1. Read Coils (FC=01) – read bits (0/1) starting at a given address.
  2. Write Multiple Registers (FC=16) – write 16-bit words starting at a given address.

Flag

We follow the TCP stream and from Packet 129 we can start reading the flag HTB{xxx}, word by word.